Use one record per site inspection. Fields marked * are required.

Job Shack / Site

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Emergency contact numbers are posted and current.
Emergency evacuation plans are posted and understood.
Required OSHA and site safety signs are posted.
Panels are labeled, accessible, and have covers closed; required working clearance is maintained.
First aid supplies are fully stocked; the first aid booklet and blood spill kit are available.
Applicable structural steel erection plans and required site-specific planning are available.
SDS information is readily accessible to workers during each shift.

Fire Extinguishers

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Extinguishers are charged, secured with an intact pin/seal, accessible, and free of hose or canister damage. Replace defective units. Follow the original Roers 75-ft site spacing criterion where applicable AND verify rating, area, floor and hazard coverage under 1926.150; spacing alone is not sufficient. Record each unit in the log below.
Drag & Drop Files, Choose Files to Upload
Record each extinguisher/location and who inspected it. Add any correction and completion date.

Housekeeping / Miscellaneous

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Sanitary, accessible facilities meet the workforce count and 1926.51(c) Table D-1: 20 or fewer workers: one facility; 20 or more: one toilet seat and one urinal per 40 workers; 200 or more: one seat and one urinal per 50 workers. Apply any stricter site/local requirements.
Walkways are clear of trip and slip hazards; work areas are picked up.
Materials are stacked and secured against sliding, falling, or collapse.
Exposed rebar and other impalement hazards are eliminated or effectively guarded; caps used for impalement protection are rated for that purpose.
Work areas throughout the building and site are kept clean and picked up.
Lighting is adequate for the task; fixtures function and are protected as needed.
Required PPE is available, suitable for the task, and used, including eye, foot, and head protection.

Electrical / Tool Safety

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Cords are undamaged, without exposed conductors; required grounding prongs are intact.
Cords are routed or protected to prevent trip hazards, pinching, and damage at pathways, doors, and walls.
Electrical connections are kept out of water and protected for the environment.
Required GFCI protection or an applicable compliant assured equipment grounding conductor program is in use.
Required guards are installed, functional, and used on saws and other tools.
Power tools have effective grounding or approved double insulation as applicable.

Working at Heights

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
A competent person has inspected scaffolds before the shift and after events affecting integrity. Foundations, base plates, pins, bracing, platforms and guardrails are sound; mobile wheels are locked. Ties and bracing follow design/manufacturer and OSHA criteria, rather than a fixed number of frame sections.
Fall protection is provided at the applicable trigger for the activity, including the general construction 6-ft trigger where applicable. Scaffold, steel erection, ladder and lift rules have task-specific requirements; follow stricter site rules.
Required toprails, midrails and falling-object protection are installed. For Subpart M guardrails, toprail height is 42 in +/- 3 in above the walking/working level; use the applicable standard for scaffolds and other systems.
Where used, harnesses, connectors and approved anchorages are inspected and correctly connected; clearance and prompt rescue are addressed.
Ladders are sound and free of damage, grease, dirt, and other slip hazards.
Portable ladders used for access extend at least 3 ft above the landing, or the permitted secured-ladder/grasping-device alternative is provided; ladders are secured as needed.
Pre-use inspections are complete; guardrails and gates are sound. Fall protection follows the lift type, manufacturer instructions, and applicable standards; do not assume identical harness rules for scissor and boom lifts.
Openings meeting the hole definition (2 in or more in their least dimension) are guarded or covered as required. Covers are secured, load-capable, and marked HOLE or COVER or color-coded as permitted.

Excavations

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Openings meeting the hole definition (2 in or more in their least dimension) are guarded or covered as required. Covers are secured, load-capable, and marked HOLE or COVER or color-coded as Slopes and configurations match the soil, conditions, and selected design/data. A 1:1 slope is not universally safe: the Appendix B Type C simple slope maximum is 1.5 horizontal to 1 vertical; Appendix B benching is not used in Type C soil.
Workers remain clear of overhead loads and loads handled by lifting or digging equipment.
Trenches 4 ft or more deep have a ladder, stairway, ramp, or other safe means of egress within 25 ft of lateral travel.
An adequate protective system is provided unless entirely in stable rock, or less than 5 ft deep with a competent-person examination showing no potential cave-in. Systems and design/data cover actual depth, soil and loads; use the separate excavation inspection for details.

Hazardous Materials

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Cylinders are secured upright as required, protected from damage, and have valve protection caps in place when required; transport and use follow applicable rules.
Hazardous chemical containers and secondary containers have required labels; any immediate-use exception is verified.
Materials are stored and secured to prevent falling containers, spills, and incompatible chemical contact.

Winter Housekeeping

Answer every item. Explain each deficiency and indicate whether the superintendent was informed. Findings can be submitted while corrections are still open.
Snow, ice, and slippery surfaces are controlled; walkways are maintained.
Toilet heating, where needed under the site plan or local requirements, is provided safely with appropriate heater clearances and ventilation.
Where combustion sources could create a CO hazard, ventilation, safe equipment placement, and appropriate carbon monoxide (CO) monitoring are provided. CO is different from carbon dioxide (CO2).
Ice melt or sand is readily available where needed, with responsibility for application assigned.

Review & Sign Off

Drag & Drop Files, Choose Files to Upload You can upload up to 6 files.
Attach up to 6 photos. Add a caption and link each to an inspection item or additional hazard. Photos are saved with the submitted record and restricted to Roers staff.

Committee Review

Record the findings as observed. Deficiencies do not prevent submission and can remain open for discussion at the committee meeting.

Follow the project plan, applicable design/data, manufacturer instructions, and state/site requirements. This checklist supports the inspection; it does not replace those requirements.

OSHA References: Guardrails | Protective Systems| Sanitation | Fire Protections